2016年8月31日星期三

3 core flexible cu/pvc/pvc RVV electric wire and cable 16mm/10mm/8mm

Conductor:
26 AWG thru 16AWG,solid or stranded
Insulation:
200°C silicone rubber,uniform,free stripping,easy to remove
Sheath:
Lacquered braid is optional
 Applications:
Internal wiring of appliances where totally enclosed
 Compliance:
UL758,UL1581
AWM3135    200°C    600V
Designed to meet ULFT2horizontal flame test RoHS

The advantages of our company:
1) Our company is a professional supplier of various kinds of cables.
2)  The quality of our products are guaranteed. They are all with CCC, CE, CB and RoHS certificates.
3)  The price is averagely 10%~20% lower than the other competitors.
4)  Huge Inventory Allows Us To Ship Your Order Immediately
5)  Our employees are all capable and professinal. They can offer you the Prompt Courteous Service.
6) We ship worldwide.
 Related pictures about the  rubber cable.

Standard:
Our products are produced according to the standards of GB, IEC, BS, DIN, ASTM, JIS, NF, AS/NZS, CSA and so on.Meanwhile we can produce based on customers' requirements and specifications.
Certificate:
The company has passed ISO90012008 quality certification, CCC China Compulsory Certification, National ElectricalProduct Safety Certification, State Construction and ProjectCommitee Recommended Manufacturer of the Transformationof Urban and Rural Power Grid Construction.





2016年8月30日星期二

PVC Insulation and sheath copper conductor electrical house wiring

Specification:
1. The rated voltage of the wires should equal to or higher then the rated voltage of the system when wires are used at AC system. If the wires are used at DC system, the rated voltage of system should lower then 1.5 times as high as rated voltage of cable and wires. The working voltage of the system could be 1.1 times as high as the rated voltage of the cable.
2. The long term working temperature should lower then 70oC. The working temperature of BV-90 should lower then 90oC. And the laying temperature should higher then 0oC.

3. The curve diameter of the wire should longer than 8 times of the diameter of the outer diameter of cable and wires if their outer diameter is 25 mm or above. If the diameter of cable and wires is above 25 mm, the curve diameter should be at least 12 times of the outer diameter of the cable and wires.




2016年8月29日星期一

low price 4*16mmAAC Wire cable/ aluminum conductor aerial bundle cable abc cable

Abc cable 16mm Construction: 
Conductors: 3 Aluminum Conductors (per ASTM Standards B231, B232, and B399 as applicable)
Insulation: Black Extruded Cross-linked Polyethylene (XLPE)
Bare Neutral: Bare Aluminum
Abc cable 16mm Ratings and Approvals:
ANSI/ICEA Standard S-76-474
Voltage Rating: 600 Volts
Temperature Rating: 90°C
Abc cable 16mm Features and Benefits: 
Weather resistant
Abrasion resistant
Tearing resistant
Cutting resistant
Chemical resistant
Abc cable 16mm Applications:
Delivers 4-wire three phase power from secondary power line or pole-mounted transformers to service-entrance conductors
May be used as pole line secondary with service splices at the pole or mid-span.
Specifications:• B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
• B-231 Aluminum Conductors, Concentric- Lay-Stranded.
• B-232 Aluminum Conductors, Concentric- Lay-Stranded, Coated Steel Reinforced(ACSR).
• B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
• B-498 Zinc-Coated Steel Core Wire forAluminum Conductors, Steel Reinforced(ACSR).
• Duplex Service Drop cable meets or exceeds all aplicable requierements of ANSI/ICEA S-76-474. 
Welcome to visit our website: www.cables-factory.com



2016年8月28日星期日

TPS flat twin and earth wire cable

Product feature:
Conductor Type: copper  Solid,stranded           Insulation Material: PVC         Jacket: PVC
Color: Black or as per requirement,           Standard: IEC 60227, BS 6004, VDE0281, JB/T8734     Cores:2C, 3C, 2C+E, 3C+E
Certification: ISO9001/ISO14001 /OHSAS18001/CCC     Standard: AS/NZS 5000.2
Type Twin and Earth Cable, Flat Twin and Earth , LSF, LSOH, OHLS Twin & Earth Cable
Range of Nominal cross section: 1.0 mm2 ~ 16 mm2
Application: These cables are used for general wiring, unenclosed, enclosed in conduit, buried direct or in underground ducts for domestic, commercial and industrial aaplications where not subject to mechanical damage.
Constructions:
Conductor: Class 1/2 Plain annealed copper wires, solid or stranded
Insulation: V-90 PVC           Sheath: 3V-90 PVC easy tear
Core color: red and black for active core, green/yellow for earth core, white for sheath
Max. Operating Temperature: 90°C
Core Colours: Red, Black & Green/Yellow;     Red, Blue, White & Green/Yellow

2016年8月25日星期四

Low voltage armored copper core underground xlpe power cable

1. Uo/U: 450/750V, 0.6/1KV, 1.8/3KV, 3.6/6KV, 6/10KV, 8.7/15KV, 12/20KV, 18/30KV, 21/35KV, 26/35KV
2. Standard applied: IEC, GB, BS, VDE, AS/NZS, UL or as per requirement
3. Working temperature: 70~125 °C
4. Conductor: solid or stranded pure annealed copper or aluminum
5. Insulation: XLPE or PVC or PE or LSZH
6. Cores: 1~5 cores, 3+1 cores, 3+2 cores, 4+1 cores for low voltage, 1 core or 3 cores for MV power cable
7. Cross section area: 1.0~630 sqmm for single core, 1.0~300 sqmm for multicores
8. Armoure: armore type is optional, SWA (steel wire armored) or STA (steel tape armored) for multicores, AWA (aluminum wire armored) or ATA (aluminum tape armored) for single core
9. Sheath: PVC or PE or Low smoking and halogen free compounding, etc.
10. Color: black or as per requirement
11. Flame retardant or Fire resistance or Low smoking and halogen free or other properties can be available
12. Wooden drum package or as per request
13. Certificates: ISO9001, ISO14001, OHSMS18001, CE, CB, CCC, SAA, etc
14. OEM can be available
15. BDK cables have very good sales over the world, enjoying a very good reputation based on top quality and most competitive price and 5-star service. 

ISO9001/ISO14001 Medium Voltage Cu/Al Concuctor XLPEinsulated PVC Jacket power cable

1 Information for XLPE/PVC SWA Cable : a, Cores and sections 1, 2, 3, 3+1, 3+2, 3+3, 4, 4+1, 4+2, 5 and so on. No. Of Core and Sectional Area(mm2) : 1 Core 1.5-800 25-800 25-1200 25-1200 35-1200 50-1200 50-1200 50-1200 2 Core 1.5-185 25-185 3 Core 1.5-400 25-400 25-400 25-400 35-400 50-400 50-400 50-400 4 Core 2.5-400 25-400 5 Core 2.5-400 25-400 b, Construction for XLPE/PVC SWA Cable : Conductor: Solid or stranded copper Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC) Filler: Polypropylene filament with lapped binding tape Binder: Binding tape Inner sheath: Polyvinyl chloride (PVC) Amour: Galvanized steel wire armored(SWA) or steel tape armored(STA) Sheath: Polyvinyl chloride (PVC) c, Nominal Section for XLPE/PVC SWA Cable : Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 d. Operating Features for XLPE/PVC SWA Cable : 1)The maximum conductor operating temperature: 90°C During short circuit (lasting less than 5 seconds) the maximum temperature of the cable conductor shall not be above 250°C Environment temperature should be no lower than 0°C for laying the cable. 2)Bending Radius of the Cable: Single Core Cable: Non Armored Cable 20D, Armored Cable 15D Cores Cable: Non Armored Cable 15D, Armored Cable 12D. Remarks: D means practical external diameter of the cable e, Features for XLPE/PVC SWA Cable : XLPE insulated power cable do not has excellent electric, mechanical properties,but also has powerful resistance against chemical corrosion,heat resistance and enviromental stress resistance. Its structure is simple. The long period operating temperature is +90 °C. It is conveninet to use and can be laid with no restriction of different level. XLPE insulated steel wire armoured power cable: XLPE/PVC insulated power cable has a number of advantages over paper insulated and PVC insulated cable. XLPE cable has high electric strength, mechanical strength, high-ageing resisting, environmetal stress resisting antichemical corrossion, and it is simple construction, using convenient and higher operating of long term temperature. It can be laid with no drop restriction. Various of flame-retardant and non-flame retardant XLPE cable can be manufactured with three technology(peroxide, silane and irradiation crosslinking). The flame-retardant cable covers all kinds of low-smoke low-halogen low-smoke halogen free, and non-smoke nonhalogented and three classes of A, B, C. 2 Standard: IEC60502,and BS6346, VDE, AS/NZS, UL,etc or as customer's request. 3 The Rated Voltage(kv): 1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35 2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 - 26/35 4 Application: 1)These cables are most suitable for direct burial or for installation on trays or ducts, Where there is a risk of mechanical damage, armoured cables should be used. 2) For laying in ground along route with large difference of level able to bear external mechanical forces.

ISO9001/ISO14001 Medium Voltage Cu/Al Concuctor XLPEinsulated PVC Jacket power cable

1 Information for XLPE/PVC SWA Cable : a, Cores and sections 1, 2, 3, 3+1, 3+2, 3+3, 4, 4+1, 4+2, 5 and so on. No. Of Core and Sectional Area(mm2) : 1 Core 1.5-800 25-800 25-1200 25-1200 35-1200 50-1200 50-1200 50-1200 2 Core 1.5-185 25-185 3 Core 1.5-400 25-400 25-400 25-400 35-400 50-400 50-400 50-400 4 Core 2.5-400 25-400 5 Core 2.5-400 25-400 b, Construction for XLPE/PVC SWA Cable : Conductor: Solid or stranded copper Insulation: Cross-linked polyethylene (XLPE) or Polyvinyl chloride (PVC) Filler: Polypropylene filament with lapped binding tape Binder: Binding tape Inner sheath: Polyvinyl chloride (PVC) Amour: Galvanized steel wire armored(SWA) or steel tape armored(STA) Sheath: Polyvinyl chloride (PVC) c, Nominal Section for XLPE/PVC SWA Cable : Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800 d. Operating Features for XLPE/PVC SWA Cable : 1)The maximum conductor operating temperature: 90°C During short circuit (lasting less than 5 seconds) the maximum temperature of the cable conductor shall not be above 250°C Environment temperature should be no lower than 0°C for laying the cable. 2)Bending Radius of the Cable: Single Core Cable: Non Armored Cable 20D, Armored Cable 15D Cores Cable: Non Armored Cable 15D, Armored Cable 12D. Remarks: D means practical external diameter of the cable e, Features for XLPE/PVC SWA Cable : XLPE insulated power cable do not has excellent electric, mechanical properties,but also has powerful resistance against chemical corrosion,heat resistance and enviromental stress resistance. Its structure is simple. The long period operating temperature is +90 °C. It is conveninet to use and can be laid with no restriction of different level. XLPE insulated steel wire armoured power cable: XLPE/PVC insulated power cable has a number of advantages over paper insulated and PVC insulated cable. XLPE cable has high electric strength, mechanical strength, high-ageing resisting, environmetal stress resisting antichemical corrossion, and it is simple construction, using convenient and higher operating of long term temperature. It can be laid with no drop restriction. Various of flame-retardant and non-flame retardant XLPE cable can be manufactured with three technology(peroxide, silane and irradiation crosslinking). The flame-retardant cable covers all kinds of low-smoke low-halogen low-smoke halogen free, and non-smoke nonhalogented and three classes of A, B, C. 2 Standard: IEC60502,and BS6346, VDE, AS/NZS, UL,etc or as customer's request. 3 The Rated Voltage(kv): 1st class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35 2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 - 26/35 4 Application: 1)These cables are most suitable for direct burial or for installation on trays or ducts, Where there is a risk of mechanical damage, armoured cables should be used. 2) For laying in ground along route with large difference of level able to bear external mechanical forces.

2016年8月23日星期二

shielded 6 core control cable

1.Standard:
The control cable can be produced according to the standard GB9330-1988,IEC,DIN,BS,and the factory can also manufacture the cables in accordance with other standards.
2.Scope of Application:
The control cable are suitable for the wiring of electrical controlling equipments and instrument,monitoring and controlling return circuit,electrical protection and measurement in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.
3.Service Conditions:
(1) The long-time working temperature of conductor of PVC insulated cable is 70oC
The long-time working temperature of conductor of XLPE insulated cable is 90oC
(2)  The temperature for laying the cables cannot be lower than 0oC.Permissible bending radius(r):unarmoured cable:r≥6D;(D: outer diameter of the cable);armoured or copper-tape screened cable:r≥12D;shielded flexible cable:r≥6D




2016年8月22日星期一

copper conductor concentric cable

Voltage:0.6/1kv
Conductor:Stranded Annealed Copper
Insulation:XLPE
Sheath:XLPE

Application: 
The concentric cable are used in service entrances replacing low voltage bundled copper cables in order to avoid energy robbery. A common way of energy robbery nowadays is using metallic claws, biting the phase and the neutral conductors, allowing the use of electricity without passing through the energy meter. However, the concentric  cable is so constructed that the use of the claws is not possible anymore. Its neutral conductor surrounding the phase like a wire armoring does not allow any contact with the central phase conductor without touching this concentric neutral conductor.

Construction:
Soft annealed copper conductor, class 2 stranding, XLPE inner insulation, neutral conductor applied as an armoring of soft annealed copper wires and a XLPE outer insulation.
Identification of the Insulated Conductors:
The identification is made by the color of the insulation material, being:
•Single-phase conductor: black
•Two-phase conductors: black and red
•Three-phase conductors: black, red and white
Max conductor temperatures 90° at continuous service, 130° overloaded and 250° at short-circuit.

Copper Conductor Concentric Cable parameter:
IEC 60502-1 IEC 60228 600/1000v
Size (mm2)
Structure Size mm
Copper cable (kg/km)

Concuctor
Insulation
Concentric conductor
Outer sheath


Single wire
Dia.
PVC
Single wire
UV-PVC


No.
Dia.

Thick
No.
Dia.
Thick
Dia.
(kg/km)
10
7
1.35
4.05
1.55
20
0.85
1.4
11.79
301.55
16
7
1.7
5.1
1.55
32
0.85
1.4
12.84
431.7
25
7
2.14
6.42
1.6
29
1.13
1.5
15.02
647.46
16
7
1.7
5.1
1.55
26
1.13
1.4
13.42
244.16
25
7
2.14
6.42
1.6
29
1.13
1.5
15.02
307.3
35
19
1.53
7.65
1.65
27
1.35
1.6
16.99
390.15

IEC 60502-1 IEC 60228 600/1000v
Size (mm2)
Structure Size mm
Copper cable (kg/km)

Concuctor
Insulation
Concentric conductor
Outer sheath


Single wire
Dia.
PVC
Single wire
UV-PVC


No.
Dia.

Thick
No.
Dia.
Thick
Dia.
(kg/km)
10
7
1.35
4.05
1.55
20
0.85
1.4
11.79
301.55
16
7
1.7
5.1
1.55
32
0.85
1.4
12.84
431.7
25
7
2.14
6.42
1.6
29
1.13
1.5
15.02
647.46
16
7
1.7
5.1
1.55
26
1.13
1.4
13.42
244.16
25
7
2.14
6.42
1.6
29
1.13
1.5
15.02
307.3
35
19
1.53
7.65
1.65
27
1.35
1.6
16.99
390.15