2016年9月2日星期五

Flexible Power cable H03VV-F 300V 2X0.5mm² 2x0.75mm² 3x0.5mm² 3x0.75mm² 0.15mm copper wire PVC insulation and sheath

The products can be used for power,lighting or telecommunication equipment,household electric appliance,meter and instrument,etc.

A. Uo/U is 450/750 and 300/500. 
B. Long time working temperature of or below 70°C is required for all cables or wires,except Model No BV-90 that can stand temperature up to 90°C.
C. Temperature should be above 0°C when laying the cables or wires.
Nominal section
(mm2)
Number/diameter of core
(mm)
Maximum outer diameter
(mm2)
Reference weight
(Kg/km)
Conductor resistance at 20°C
≤(Ω/km)
copper
aluminum
aluminum
copper
1.5(A)
1/1.38
3.3
20.3
-----
-----
12.1
1.5(B)
7/0.52
3.5
21.6
-----
-----
12.1
2.5(A)
1/1.78
3.9
31.6
17
11.80
7.41
2.5(B)
7/0.68
4.2
34.8
-----
-----
7.41
4(A)
1/2.25
4.4
47.1
22
7.39
4.61
4(B)
7/0.85
4.8
50.3
------
-----
4.61
6(A)
1/2.76
4.9
65
29
4.91
3.08
6(B)
7/1.04
5.4
71.2
----
----
3.08
10
7/1.35
7.0
119
62
3.08
1.83
16
7/1.70
8.0
179
78
1.91
1.15
25
7/2.04
10.0
281
118
1.20
0.727
35
7/2.52
11.5
381
156
0.868
0.524
50
19/1.78
13.0
521
215
0.641
0.387
70
19/2.14
15.0
734
282
0.443
0.268
95
19/2.52
17.5
962
385
0.320
0.193

More Information from: www.cables-factory.com






2016年9月1日星期四

Copper Core XLPE Insulated and sheath Duplex Service Drop Cable

1. Application:
NYCY cables are used in power plants, industrial and switching installations, for street lighting, domestic power supply connections, in secondary distribution networks and other. These cables are preferentially used for underground application as well as for interior installation in room and cable ducts and for outdoor and applications, for indoor installations, in the open air, underground and in water where greater mechanical protection an protection against accidental contact is required if damaged.
2.  Technical data:
Conductors: Stranded Annealed Copper
Insulation: XLPE (Cross-linked Polyethylene) 
Concentric layer: Single layer of plain annealed copper wires
Sheath/Jacket: PE(Polyethylene) or XLPE (Cross-linked Polyethylene) 
Common Used Colours:
For insulation: Blue, Black and Red. 
For external jacket: Black
Voltage: 600 volts 

Operating temperature: Maximum 90°C, minimum -30°C
3. Executive standard:
VDE0276 part 603, CENELEC HD603 S1, IEC 60502
7 cores and above to VDE0276 part 627, CENELEC HD627 S1, IEC 60502 upon request.
ASTM 600/1000v
Core
AWG
Structure Size (mm)
Copper cable (kg/km)
Conductor
Insulation
Concentric conductor
Outer sheath
Single wire
XLPE
Single wire
UV-PVC
No.
Dia.
Thick
No.
Dia.
Thick
Dia.
1
16
7
0.49
1.14
39
0.321
1.14
6.82
81.46
1
10
7
0.98
1.14
34
0.511
1.14
8.67
172.04
1
8
7
1.23
1.14
25
0.643
1.14
9.68
221.58
1
6
7
1.55
1.14
25
0.813
1.14
10.98
160.50
1
4
7
1.96
1.14
27
1.020
1.14
12.62
509.26
          
          
IEC 60502-1 IEC 60228 600/1000v
Size (mm2)
Structure Size mm
Copper cable (kg/km)
Concuctor
Insulation
Concentric conductor
Outer sheath
Single wire
Dia.
PVC
Single wire
UV-PVC
No.
Dia.
Thick
No.
Dia.
Thick
Dia.
(kg/km)
10
7
1.35
4.05
1.55
20
0.85
1.4
11.79
301.55
16
7
1.7
5.1
1.55
32
0.85
1.4
12.84
431.7
25
7
2.14
6.42
1.6
29
1.13
1.5
15.02
647.46
          
16
7
1.7
5.1
1.55
26
1.13
1.4
13.42
244.16
25
7
2.14
6.42
1.6
29
1.13
1.5
15.02
307.3
35
19
1.53
7.65
1.65
27
1.35
1.6
16.99
390.15