Description
email is:sales@hlcablles.com
1.The long-time permissible working temperature of cable conductive core is not more than 70 °C.
2.During short circuit (max. permanent time is not more than 5 seconds), the max temperature of cable conductor is not more than 165°C.
3.The difference level of laying cable is not restricted.When laying the cable,ambient temperature is not lower than 0°C.
4.They have good chemical stability,and properties of acid resistance,alkali resistance,salt resistance,oil resistance,solvent resistance and flame resistance.rty
5.Light weight,good bending property and easy installation and maintenance.
Application
The products is suitable for use in power installations, fixed wiring or flexible
connections for electrical appliances like lighting, electronic equipment, instrument
and communication equipment with rated voltage 450/750V or less
Standard
GB 5023.11997 , JB 8734.15-1998, Q/ZEL 02-2002, GB 5023.17-1997, IEC227
Construction of the electrical wiring(or pvc insulated wire)
1- Flexible Copper Conductor, Solid or Stranded Copper Conductor.
Class 1, Class 2, Class 5 flexible copper conductor
2- PVC Insulation
3. PVC filling
4- PVC outer sheath
5- Rated Voltage Uo/U (Um):300/500V,450/750V
Class 1, Class 2, Class 5 flexible copper conductor
2- PVC Insulation
3. PVC filling
4- PVC outer sheath
5- Rated Voltage Uo/U (Um):300/500V,450/750V
Colors Available:
Color Code #1) Black, White, Red, Blue, Green, Orange, Yellow, Brown, Purple, Gray, Pink, Tan
Color Code #2) Black, White, Red, Blue, Green, Orange, Yellow, Brown, Gray
Color Code #3) Black, White, Red, Green
Color Code #4) Black, Green
Color Code #5) Black
Color Code #1) Black, White, Red, Blue, Green, Orange, Yellow, Brown, Purple, Gray, Pink, Tan
Color Code #2) Black, White, Red, Blue, Green, Orange, Yellow, Brown, Gray
Color Code #3) Black, White, Red, Green
Color Code #4) Black, Green
Color Code #5) Black
Specification
300/500V,Copper Conductor PVC Insulated Wire | |||||
Nominal Cross Section
|
Conductor Construction
|
Insulation Thickness
|
Overall Diameter
|
Approx. Net Weight
| |
mm2
|
No.
|
Diameter
|
mm
|
mm
|
kg/km
|
1 X 0.5
|
1
|
0.8
|
0.6
|
2.00
|
8.16
|
1 X 0.75
|
1
|
0.97
|
0.6
|
2.17
|
10.71
|
1 X 1.0
|
1
|
1.13
|
0.6
|
2.33
|
13.48
|
300/500V, Copper Conductor Heat Resistant PVC Insulated Connecting Wire at 90C
| |||||
Nominal Cross Section
|
Conductor Construction
|
Insulation Thickness
|
Overall Diameter
|
Approx. Net Weight
| |
mm2
|
No.
|
Diameter
|
mm
|
mm
|
kg/km
|
1 X 0.5
|
1
|
0.8
|
0.6
|
2.00
|
8.16
|
1 X 0.75
|
1
|
0.97
|
0.6
|
2.17
|
10.71
|
1 X 1.0
|
1
|
1.13
|
0.6
|
2.33
|
13.48
|
1 X 1.5
|
1
|
1.38
|
0.7
|
2.78
|
19.70
|
1 X 2.5
|
1
|
1.78
|
0.8
|
3.38
|
31.20
|