35mm 50mm 95mm 120mm 150mm 185mm 240mm XLPE SWA PVC power supply cable Armoured 4 Core Power .
please leave me messages ,
we will send you the price list .
email id :sales@hlcables.com
2016年10月26日星期三
2016年10月24日星期一
2016年10月18日星期二
2016年10月7日星期五
NA2XRY 4 cores 0.6/1 KV International : IEC 60502-1 16~300mm2.
NA2XRY
- Voltage:0.6/1 KV
- Core:4 cores
- Size: 16~300mm2
- Conductor: Aluminum
- Insulation: XLPE
Related Recommendations
ominal | Number and | Nominal | Maximum Permissible | Standard | Weight | Delivery | |
Cross Sectional | Diameter of Wire | Overall | Current Rating | Delivery | per Standard | on Wooden | |
Area | Diameter | Amp | Length | Delivery L | Drum | ||
mm² | No x mm | mm | In Ground @ 20°C | In Air @ 30°C | m | kg | |
4 x 16 | 7 x 1.70 | 23.1 | 87 | 77 | 1000 | 803 | R14 |
4 x 25 | 7 x 2.14 | 27.2 | 111 | 97 | 1000 | 1078 | R16 |
4 x 35 | 7 x 2.58 | 25.6 | 134 | 120 | 1000 | 1147 | R16 |
4 x 50 | 19 x 1.83 | 28.7 | 160 | 146 | 1000 | 1405 | R16 |
4 x 70 | 19 x 2.20 | 32.6 | 197 | 187 | 1000 | 1805 | R18 |
4 x 95 | 19 x 2.58 | 36.6 | 234 | 227 | 500 | 1155 | R18 |
4 x 120 | 37 x 2.08 | 40.1 | 266 | 263 | 500 | 1386 | R18 |
4 x 150 | 37 x 2.30 | 44.4 | 300 | 304 | 500 | 1673 | R20 |
4 x 185 | 37 x 2.58 | 49.2 | 337 | 347 | 500 | 1793 | R22 |
4 x 240 | 61 x 2.30 | 52.7 | 389 | 409 | 500 | 2507 | R25 |
4 x 300 | 61 x 2.58 | 60.2 | 440 | 471 | 400 | 2443 | R25 |
Construction characteristics | |
Insulation | XLPE (Cross-linked Polyethylene) |
Outer sheath | PVC |
Inner sheath | PVC |
Electrical characteristics | |
Rated Voltage Uo/U (Um) | 0.6/1 kV |
Max. system voltage, 1-phase grounded | 0.7kV |
Max. system voltage 3 phases (Um) | 1.2kV |
Mechanical characteristics | |
Mechanical resistance to impacts | Very good |
Usage characteristics | |
U.V resistance | if required |
Flame retardant | IEC 60332-3 Cat. A |
Bending factor when laying | 10(xD) |
Minimum installation temperature | 90°C |
Max. conductor temperature in service | 90°C |
Short-circuit max. conductor temperature | 250°C |
2016年10月6日星期四
U500 SV (H07 V-K)
- Voltage:450/750V
- Core:single or multi
- Size: 0.75~150mm2
- Conductor: Copper
- Insulation: PVC
Related Recommendations
Standards
International : IEC 60227-2
National : NF C 32-201/3
Description
Application
H07V-K cors are used for panels and cabinets stranding.
Installation
email is sales@hlcables.com
tel is 0086-0371-66766667
Construction characteristics | |
Insulation | PVC |
Conductor material | Bare copper |
Electrical characteristics | |
Rated Voltage Uo/U (Um) | 450 / 750 V |
Mechanical characteristics | |
Mechanical resistance to impacts | Low |
Cable flexibility | Flexible |
Usage characteristics | |
Max. conductor temperature in service | 70°C |
Short-circuit max. conductor temperature | 160°C |
Operating temperature, range | -5 .. 60°C |
Weather resistance | Good |
Flame retardant | C2, NF C 32-070 |
Chemical resistance | Accidental |
Water proof | Accidental |
Bending factor when laying | 4(xD) |
2016年10月4日星期二
IEC60227 copper House Cable
Product feature:
Conductor Material/Type: copper Solid/stranded/flexible Core: 1/2/3/4, Voltage: 300/500v 450/750v, Insulation/Jacket Material: PVC
Style: Flat/round/twin and earth wire, Standard: IEC, BS, UL, VDE, AS/NZS, JIS, etc, Specification: Electric Wire 2.5mm2, 1.5mm2,etc
Length: 100M 200M 300M 500M Color: Green Red Yellow Black Green etc.
Description:
1.Max. Permissible Continuous Operation Temperature of The Conductor: 70°C; 2..The Ambient Temperature Under Installation Should Not Below 0°C
3.Impedance (ohms): 100±2ohm 4. Fixed -40°C to 90°C / Flexing -2
Application:
House wire Cables are suitable for household electrical appliances, small electric power tools, AC rated voltage up to and including 450/750V, and below the small household electrical appliances, electric tools, instruments and apparatuses and lighting devices, which is used for connecting power line.
Parameter 1:
Nominal
|
Conductor
|
Nominal
|
Max.overall
|
Condcutor
|
Min.insulated
|
Weight
|
sectional area
|
No/Dia.
|
Insulated thickness
|
Dia.
|
Resistance at
|
resistance at
|
Kg/km
|
mm2
|
mm
|
mm
|
mm
|
20
|
70MΩ/km
| |
2.5
|
9/0.41
|
0.8
|
4.2
|
7.41
|
0.011
|
33
|
4
|
19/0.52
|
0.8
|
4.8
|
4.61
|
0.009
|
48
|
6
|
19/0.64
|
0.8
|
5.6
|
3.08
|
0.0084
|
68
|
10
|
49/0.52
|
1
|
7.6
|
1.83
|
0.0072
|
115
|
16
|
49/0.64
|
1
|
8.8
|
1.15
|
0.0062
|
176
|
25
|
98/0.58
|
1.2
|
11
|
0.727
|
0.0058
|
272
|
35
|
133/0.58
|
1.2
|
12.5
|
0.524
|
0.0052
|
384
|
50
|
133/0.68
|
1.4
|
16.5
|
0.387
|
0.0051
|
510
|
70
|
189/0.68
|
1.4
|
16.5
|
0.268
|
0.0045
|
714
|
95
|
259/0.68
|
1.6
|
19.5
|
0.139
|
0.0035
|
965
|
120
|
259/0.76
|
1.8
|
22
|
0.153
|
0.0032
|
1210
|
150
|
259/0.85
|
1.8
|
25
|
0.124
|
0.0032 1348
|
Parameter 2:
Product Name
|
Solid/flexible Copper PVC house building wire Cable
|
Product standard
|
AS/NZS 5000.2 / IEC60227
|
Core
|
1/2/3/4cores
|
Operating temperature
|
-40 °C~90°C
|
Type of conductor
|
Class 5
|
Material of conductor
|
Copper/Aluminum
|
Material of insulation
|
PVC 5V-90/Rubber
|
Color of core insulation
|
Red/White/Blue/Black/Green/Yellow(Optional)
|
Material and Color of Jacket
|
PVC/Rubber/As your requirement
|
Rated Voltage
|
250/440V 300/500V 450/750V
|
Advantage
|
Easy to strip and terminate
|
Section
|
0.75mm2~240mm2
|
Popular Application
|
Fire Alarm / OWS & EWIS panels to detectors / Speakers / Horns / Field modules
|
订阅:
博文 (Atom)