2017年2月10日星期五

flame resistant xlpe insulated steel wire armoured 6/10kv 3*185mm2 ,0.6/1kv 4*2.5mm2 4*4mm2 ZR-YJV 32 ,300v-500v 12TRLAD+SH 3*0.75MM2 zr-djyjp3vp3-32


Specifications

1. 16 Years Experience.
2. High Quality With Good Price
3. GB12706,IEC60502, ISO,UL,BS, DIN, ICEA,VDE,.
Copper/Aluminum Conductor XLPE Insulated PVC(PE)Sheathed Power Cable 
 
Standard:

The cable is manufactured according to the standard GB12706-91 or IEC 60502. It's suitable to be installed in the power transmission and distribution lines with rated voltage of 0.6/1KV(U0/U). 


Application conditions:

1. The long-time permissible operation temperature of conductor shall not be higher than 90oC.
2. Conductor maximum short circuit (not more than 5 seconds) temperature shall not be higher than 250 oC.
3. The power cable is not limited by drop in level when being laid, and the ambient temperature shall not be lower than 0 oC.
4. The minimum bending radius shall not be less than 10 times of the cable overall diameter when being laid.


Note: We can also produce these kinds of cables with flame-retardant, fire-resistant, anti-termite, low smoke and non-halogen cables, respectively according to the requirements of customers.

Type, Description and Application 

TypeDescriptionApplication 
Cu CoreAl Core
YJYYJLYCu(Al)Core,XLPE Insulated,PE Sheathed Power CableCan be laid in indoor, outdoor, tunnels, cable channels, reinforced concrete pipelines and loose soil. Cable should not bear external mechanical force, but can bear a certain pulling force. It is impermissible to lay single core cable in magnetic ducts.
YJVYJLVCu(Al)Core,XLPE Insulated,PVC Sheathed Power Cable
YJV22YJLV22Cu(Al)Core,XLPE Insulated,Steel Tape Armored,PVC Sheathed Power CableCan be laid in indoor, outdoor, tunnels, cable channels, reinforced concrete pipelines and underground. Cable can bear external mechanical force, but should not bear large pulling force. It is impermissible to use single core cable in places with A.C circuit.
YJV23YJLV23Cu(Al)Core,XLPE Insulated,Steel Tape Armored,PE Sheathed Power Cable
YJV32YJLV32Cu(Al)Core,XLPE Insulated,Thin Steel Wire Armored,PE Sheathed Power CableCan be Laid in indoor, tunnels, vertical section, mines and water. Cable can bear external mechanical force and moderate pulling force.
YJV33YJLV33Cu(Al)Core,XLPE Insulated,Thin Steel Wire Armored,PE Sheathed Power Cable
YJV42YJLV42Cu(Al)Core,XLPE Insulated,Thick Steel Wire Armored,PVC Sheathed Power CableCan be suited for vertical installation and laid in water or sea-bottom.Can bear greater external mechanical force and pulling force.
YJV43YJLV43Cu(Al)Core,XLPE Insulated,Thick Steel Wire Armored,PE Sheathed Power Cable
NH-YJVNH-YJLVCu(Al)Core,XLPE Insulated,PVC Sheathed,Fire Resistant Power CableFir resistant cables are suited for places where cables must continue to work for some time under fire condictions.Such as power station,underground,railways,talk buildings, important industrial and mining enterprise,and places related to fire fighting architecture.
NH-YJV22NH-YJLV22Cu(Al)Core,XLPE Insulated,Steel Tape Armored,PVC Sheathed,Fire Resistant Power Cable
NH-YJV23NH-YJLV23Cu(Al)Core,XLPE Insulated,Steel Tape Armored,PE Sheathed,Fire Resistant Power Cable
NH-YJV32NH-YJLV32Cu(Al)Core,XLPE Insulated,Thin Steel Wire Armored,PVC Sheathed,Fire Resistant Power Cable
ZR-YJVZR-YJLYCu(Al)Core,XLPE Insulated,PE Sheathed,Flame Retardant Power CableFlame retardant cables are difficult to be fired or they burn only in a limited range when in fire. They are suitable for the places requiring high flame retardation such as high building, hotel,oil field, coal mine, nuclear station, public place and for many explosion-proof places.
ZR-YJYZR-YJLYCu(Al)Core,XLPE Insulated,PVC Sheathed,Flame Retardant Power Cable
ZR-YJV22ZR-YJLV22Cu(Al)Core,XLPE Insulated,Steel Tape Armored,PVC Sheathed,Flame Retardant Power Cable
ZR-YJV23ZR-YJLV23Cu(Al)Core,XLPE Insulated,Steel Tape Armored,PE Sheathed,Flame Retardant Power Cable
ZR-YJV32ZR-YJLV32Cu(Al)Core,XLPE Insulated,Thin Steel Wire Armored,PVC Sheathed,Flame Retardant Power Cable
ZR-YJV33ZR-YJLV33Cu(Al)Core,XLPE Insulated,Thin Steel Wire Armored,PE Sheathed,Flame Retardant Power Cable
ZR-YJV42ZR-YJLV42Cu(Al)Core,XLPE Insulated,Thick Steel Wire Armored,PVC Sheathed,Flame Retardant Power Cable
ZR-YJV43ZR-YJLV43Cu(Al)Core,XLPE Insulated,Thick Steel Wire Armored,PE Sheathed,Flame Retardant Power Cable

2017年2月9日星期四

vde flat electrical cables and wires h03vvh2-f 0.5mm*2c


Applications:  
Flexible insulated conductor used for laying in electric-installation tubes, under
and in closed installation conduits. Direct laying in cable guides is not permitted.
Also applied for internal wiring of distribution and switching boxes equipment, 
same as for protective laying for lighting of nominal voltage up to 1000 V alternating current

Design:Conductor : stranded copper class 5 according to DIN VDE 295
2 Insulation : PVC-compound TI1 according to DIN VDE 0281, part 1
Standard DIN VDE 0281 part 1; DIN VDE 0281 part 3; DIN VDE 0293; DIN VDE 0295.

Application
Flexible cable for medium mechanical stresses. Permitted frequent bending and twisting. 
Specially suitable for application in household  kitchens and offices in dry and damp conditions,
for inst. washing-machines, dryers, refrigerators etc

Standards: HRN HD 21.5 S3,  IEC 60227-5,  DIN VDE 0281 part 5
Construction:
              Conductor:  bare copper conductor, fine wired stranded, class 5 acc. to DIN VDE 0295
              Insulation:  PVC compound TI2 acc. to DIN VDE 0207 part 4/ HD 21.1 S4, 
              Sheath:  PVC compound TM2 for flexible cables acc. to DIN VDE 0207 part 5 / HD 21.1 S4
              sheath colour:     white or black
              Core colour marking:     HRN HD 308 S2 / VDE 0293-308.

Conductor:
Class 1 for re: round solid plain copper conductor, single wire to VDE0295
Class 2 for rm: round stranded plain copper conductor, multi wire to VDE0295
Class 2 for sm: sectorial stranded plain copper conductor to VDE0295
Insulation:XLPE (Cross-linked Polyethylene)
Filler: Halogen free compound
Sheath: XLPE (Cross-linked Polyethylene)
Sheath Colour:White
Voltage Rating:300/500V
Temperature Rating:0°C to +70°C
Minimum Bending Radius: 4 x overall diameter
Core Identification:
Up to and including 5 cores: colour coded or number coded
7 cores and above: number coded.


2017年2月8日星期三

H05RN-F RUBBER CABLE/H07RN-F RUBBER CABLE/H05RR-F RUBBER CABLE

1.Standard:H05RR-F , H05RN-F , H07RN-F , H07ZZF , H01N2-D , NSSHOU , NSGAFOU , NSHXAFO , HO7RN8-F. 
2.Voltage: 300V/500V 450/750V 600/1000V
3.Rubber Sheathed Flexible Mine Cable: 
  a)Rubber Sheathed, Flexible Coal Cutter Cables
  b)Screen, Rubber Sheathed, Flexible Coal Cutter Cables
  c)Electric Drill Cable For Mine
  d)Rubber Sheathed, Moveable And Flexible Mine Cables
4.General Rubber Sheathed Flexible Cable
a)Common Rubber Sheathed Flexible Cable
b)Common Chloroprene Cabtyre Flexible Cables.
c)Medium Duty Rubber Sheathed Flexible Cables
d)Heavy Duty Rubber Sheathed Flexible Cables
5.Applications
 Mobile appliances, lighting, electrical equipment cable boxes
  Mining, construction, shipyards, oil,steel,industry,
  electrical equipment in construction  field work 
6.Model type
 YZ YZW :Middle modle rubber sheath flexible cable  
               used for various domestic appliance portable equipment and
               moving machinery in oil or damp environment.
 YC YCW :Heavy modle rubber sheath flexible cable which can bear larger
               machenical force effect.
7.Working Conditions
a.Rated voltage 300/500(YZ type),450V(YC type)
b.The long-term working temperature of conductor should be no longer than 65*C
c.W type cables have weather-proof character and certain grease-proof character and are suitable for outdoor usage and the occasion with greasy dirt.
d.ZR type cables have fire-retardant character.
8.Specification Range:
 Type
 Rated Voltage
 Core Number
Nominal Cross-section Area
YQ,YQW
     300/300
2.3
0.3~0.5
YZ,YZW
     300/500
2.3.4.5.3+1
1.5~6

YC

     450/750
1
2
3.4
5
1.5~240
1.5~95
1.5~150
1.5~25

YCW

   450/750
2
3
3+1
35~95
120~150
2.5~150