1.5mm 2.5mm 4mm 6mm 10mm PVC insulated PVC sheath control cable
Conductors
Conductors shall be Circular Stranded, Class 2 as per IEC 60228, BS EN 60228. Upon request, Solid Circular Conductor, Class 1 as per IEC 60228, BS EN 60228 can be supplied.
Insulation
XLPE material and thickness shall be as per IEC 60502-1 rated 90ºC for continuous operation or PVC Insulation Type A as per IEC 60502-1 or TI1 as per BS 7655 rated 70 ºC for continuous operation.
Assembly
The Insulated Conductors are laid-up together with non-hygroscopic fillers wherever necessary, the assembly is bedded with an extruded layer of PVC. In case of non-armoured cables, this layer may be omitted provided the outer shape of the cable remains practically circular.
Standard Colour Code
Single core : Red or Black
Two cores : Red, Black
Three cores : Red, Yellow, Blue
Four cores : Red, Yellow, Blue, Black
Five cores : Red, Yellow, Blue, Black, Green
Six cores & above : White numerals printed on black core insulation.
Two cores : Red, Black
Three cores : Red, Yellow, Blue
Four cores : Red, Yellow, Blue, Black
Five cores : Red, Yellow, Blue, Black, Green
Six cores & above : White numerals printed on black core insulation.
Armour (Optional)
• Galvanized Steel Wires applied helically over the bedding as per IEC 60502-1 (or BS 5467, BS 6346 as per customer requirements).
• Double Steel Tapes applied helically over the bedding as per IEC 60502-1.
• Double Steel Tapes applied helically over the bedding as per IEC 60502-1.
Screening (Optional)
• Copper Tape(s) of nominal thickness 0.05mm applied helically with suitable overlap or as per customer requirement.
• Copper Wire Screen (upon request) as per customer requirement.
• Copper Wire Screen (upon request) as per customer requirement.
Outer Sheath
PVC Type ST2 as per IEC 60502-1 and Type 9 as per BS 7655 coloured Black.
Application
Underground direct or indirect on cable tray.
Underground direct or indirect on cable tray.
Also available upon request:
a) Solid (re) Conductors
b) Control Cables with Copper Wire Screen
c) Control Cables with one core Green/Yellow
b) Control Cables with Copper Wire Screen
c) Control Cables with one core Green/Yellow
Note:
1) Based on special request for 6 cores and above, white cores with black printed numerals can also be provided.
2) Cable with one core Green/Yellow can also be provided based on special request.
2) Cable with one core Green/Yellow can also be provided based on special request.
Control Cable Tye and General Introduction
Type | description | Application Site |
KVV KYJV | Copper conductor, PVC/XLPE insulation, PVC sheath control cable | For laying doors, in trenches and in ducts, for fixed installation. |
KYJ(F)V | Copper conductor, Irradiated cross-linked insulation,PVC sheath control cable | With flame retardant property and conductor Max. temperature of 90-150°C |
KVV22 KYJV22 | Copper conductor, PVC/XLPE insulation,PVC sheath control cable with steel tape armored | For laying doors, in ground, can withstand heavier mechanical force and for fixed installation. |
KYJ(F)V22 | Copper conductor, Irradiated cross-linked insulation, PVC sheath control cable with steel tape armored | With flame retardant property and conductor Max. temperature of 90-150°C, which can withstand heavier mechanical force |
KVVP KYJVP | Copper conductor, PVC/XLPE insulation,PVC sheath with copper wire braided shield control cable | For laying doors, in trenches and in ducts, such cable has the stable structure and excellent properties of anti-interference. |
KVVP2 KYJVP2 | Copper conductor, PVC/XLPE insulation,PVC sheath with copper tape wrapped shield control cable | For laying doors, in trenches and in ducts, the cable has stable structure and excellent properties of anti-interference also can withstand heavier mechanical force. |
KVVP22 KYJVP22 | Copper conductor, PVC/XLPE insulation, PVC sheath with copper wire braided shield and Steel tape armored control cable | For laying in doors, in ground and be able to withstand heavier mechanical force and good anti-interference properties for fixed installation. |
KVVP2-22 KYJVP2-22 | Copper conductor, PVC/XLPE insulation, PVC sheath with copper tape wrapped shield and Steel tape armored control cable | For laying in doors, in ground and be able to withstand heavier mechanical force and good anti-interference properties for fixed installation. |
KVV32 KYJV32 | Copper conductor, PVC/ XLPE insulation, PVC sheath control cable with steel wire armored | For laying doors, in ground, able to withstand heavier mechanical force and for fixed installation. |
KVVP32 KYJVP32 | Copper conductor, PVC/XLPE insulation, PVC sheath/ copper wires braided shield and steel wire armored control cable | For laying doors, in ground, able to withstand heavier mechanical force and for fixed installation. |
KVVP2-32 | Copper conductor, PVC insulation, PVC sheath with Copper tape wrapped shield and steel wire armored control cable | For laying doors, in ground, able to withstand heavier mechanical force and for fixed installation. |
KVVR | Copper conductor , PVC insulation and PVC sheath flexible control cable | For laying doors, connecting movable devices which can be used for movable installation. |
KVVRP | Copper conductor, PVC insulation and PVC sheath flexible control cable with copper wire braided shield | For laying doors with good property of shielding and anti-interference, for movable installation but can’t withstand external mechanical force. |
KVVRP2 | Copper conductor, PVC insulation and PVC sheath flexible control cable with copper tape wrapped shield | For laying doors with good property of shielding and anti-interference, for movable installation but can’t withstand external mechanical force. |
NH-KVV | Copper conductor, PVC insulation and PVC sheath fire-resistance control cable | Excellent property of flame-retardance and applies to high requirements of fire-fighting situation. |